### OBSDATE ### 20100108 ### LOGDATE ### 100109 ### OBSERVERS ### ACR, MJI ### WEATHER ### Clear then cloudy. The rest of NSW seemed to be clear. ### LOCATION ### SUSI ### PROGRAM ### Work on software, get ready for observing. ### SIDEROSTATS ### n3 s2 ### TARGETS ### Achernar. But no fringes. If this persists, the LDC will have to be checked (because everything else was OK). ### PROBLEMS ### 1) With the S1 server not up, a reopen on Taskmaster caused it to crash. 2) Siderostats were not in run mode, because of an acqlabjack restart. Caused the sidcons to crash. 3) "Got sidcon mode with wrong data" is the error when putting a periscope in from the GUI. 4) Even with a new taskmaster, the acquisition system tracks on noise with "Star present: NO" 5) The gain of both the intensifier and PAVO needs adjustment based on magnitude. 6) South shutter was "MIDDLE" but PAVO had no error. 7) SNON and SNOFF still not displayed. Could be displayed on server right of "Shutter" or "Filenum" 8) When e.g. "RTP Failed after 2 tries", too many WARNING messages come up.