### OBSDATE ### 20130618 ### LOGDATE ### 130618 ### OBSERVERS ### ACR ### WEATHER ### Fine, incoming clouds ### LOCATION ### Home ### PROGRAM ### Sco-Cen ### SIDEROSTATS ### n4 s3 ### TARGETS ### Lots of mucking about to get S metrology back. Sent the cart to ~30m because I know it has been strongest there, recovered the signal, and adjusted it on the way back to zero. Bet-Cru fringes at -650um, did't take any data, just system check. Gain 200: Mu02-Sco fringes at -500um, dispersion was 1.0, but didn't want to servo on patchy fringes. Seeing is obviously not too good tonight. Gain 190: Del-Cru (hr4656) Fringes at -760um. Alf-Mus (hr 4798) Fringes at -680um. Del-Cru Gain200: Mu02-Sco (hr6252) Fringes at -580um. Still extremely patch. Cart is also having trouble at this speed (-1200). Oscillations are 1/3 of the servoplot window height. ### QUALITY ### Quite bad (no/almost no useful data ### PROBLEMS ### Metrology N and S both needed resetting.